Configuration Automation Plug-in

Tag "Batch"

Tag "settings"

TagDescriptionDefaultType

<CSVExportSheetNameBeforeTemplateName>

Controls whether the name of the worksheet should precede the file name.falseBoolean
<DontIncrementStartDateAfterError>Controls wether after an unsuccessful run, the time stamp should be incremented or not.falseBoolean
<LogConnection>If <Tracelevel> is not 0, the name of the data base connection for logging has to be specified.emptyString
<TraceLevel>

Following trace levels are available:

  • 0 -> Off. Output no tracing messages.
  • 1 -> Error. Output error messages.
  • 2 -> Warning. Output warning and error messages.
  • 3 -> Info. Output process start, process end, warning and error messages.
  • 4 -> Verbose. Output all informational, warning and error messages.

If <LogConnection> is empty the default value is 0

If <LogConnection> is not empty the default value is 4

Integer